| Wire cross-section |
0.5–1.0 mm², 1.5–2.5 mm², 4.0–6.0 mm² |
The terminal barrel must match the conductor size so the crimp can form a secure gas-tight connection. |
Confirm the wire size marking on the terminal matches the stripped conductor cross-section. |
Do not force a larger wire into a smaller barrel or rely on excessive crimping to compensate for a mismatch. |
| Common conductor equivalents |
Approximately 20–18 AWG, 16–14 AWG, and 12–10 AWG respectively |
AWG and metric wire sizes are not always exact equivalents, so the terminal marking and cable specification should take priority. |
Check the actual cable specification rather than selecting solely by visual appearance. |
Use only conductors permitted by the terminal and equipment documentation. |
| Stud or screw size |
Typical openings: M3, M4, M5, M6, or approximately #4–#10 screw sizes |
The tongue must sit flat around the fastener without excessive clearance or interference. |
Place the terminal on the fastener and verify full seating with no rocking or forced spreading. |
Never enlarge the hole by cutting, drilling, or filing unless the terminal is specifically approved for that modification. |
| Tongue style |
Standard spade, flanged spade, or locking/fork style |
A flanged or locking design can improve retention where vibration or repeated servicing is expected. |
Check that the fork cannot slip out when the screw is slightly loosened during a controlled fit test. |
Use a closed-ring terminal where local rules or the risk assessment require maximum retention. |
| Insulation type |
Non-insulated, vinyl-insulated, nylon-insulated, or heat-shrink-insulated |
The insulation support must match the terminal and the available crimp-tool cavity. |
Verify that the wire insulation enters the insulation-support section without being trapped in the conductor crimp. |
Select insulation materials compatible with operating temperature, chemicals, moisture, and voltage requirements. |
| Terminal material and plating |
Copper or copper alloy; tin plating is common for general low-voltage applications |
Material and plating influence conductivity, corrosion resistance, and compatibility with the mating hardware. |
Inspect the plating for cracks, exposed corrosion, burrs, or deformation before crimping. |
Avoid incompatible metal combinations in damp or corrosive environments unless the interface is approved for that service. |
| Strip length |
Use the terminal or tool manufacturer's specified strip length; typically about 5–8 mm for small terminals |
Incorrect strip length can leave exposed conductor or place insulation inside the conductor-crimp zone. |
After insertion, confirm that all strands are inside the barrel and that insulation is supported without entering the wire-crimp area. |
Do not nick, cut, or remove individual strands during stripping. |
| Crimp-tool compatibility |
Use a calibrated tool with a cavity matching the terminal type, insulation style, and wire range |
A correct terminal can fail if the crimp profile, height, or compression is wrong. |
Verify tool markings, inspect the crimp profile, and check that the ratchet releases only after a complete cycle. |
Do not use pliers, hammers, or an unapproved tool as a substitute for a proper crimper. |
| Pull-test quality check |
Perform a controlled axial pull test on samples from each production setup or tool change |
A pull test helps reveal incomplete crimping, damaged strands, incorrect wire size, or poor tool adjustment. |
Record wire size, terminal type, tool identification, test force, result, and failure mode. Set acceptance limits from the applicable terminal specification or test standard. |
Reject terminals that pull apart, show conductor withdrawal, or exhibit severe barrel cracking before the specified acceptance limit. |
| Crimp appearance |
Uniform compression with no open seam, excessive flash, cracked barrel, or exposed loose strands |
Visual defects can indicate incorrect die selection, over-crimping, under-crimping, or terminal damage. |
Use magnification when needed and compare the finished crimp with the approved work instruction. |
Do not reuse a terminal that has already been crimped, distorted, or removed from a fastener. |
| Fastener fit and torque |
Use the equipment or terminal assembly torque specification; do not estimate critical torque by feel |
Under-torque can cause loosening and heating; over-torque can deform the terminal or damage the threaded joint. |
Check that the tongue remains flat after tightening and that no insulation is trapped beneath the contact area. |
Apply power only after the connection has been inspected and the circuit has passed continuity and insulation checks. |
| Electrical verification |
Continuity check, polarity check where applicable, and low-resistance verification for critical circuits |
Mechanical retention alone does not prove that the connection has acceptable electrical performance. |
Confirm stable readings and investigate any unexpected resistance increase, intermittent continuity, or heating under load. |
De-energize the circuit before any rework and follow the applicable electrical isolation procedure. |
| Environmental suitability |
Indoor dry use, vibration exposure, moisture, outdoor use, or high-temperature service |
Vibration, humidity, chemicals, and temperature can change the required insulation, plating, retention, and sealing approach. |
Compare the terminal's documented ratings with the actual installation environment and duty cycle. |
Use sealed or protected connection systems where moisture, contamination, or condensation is expected. |